Your current location:Home / Product / Life science instruments / Electrophoretic imaging / Fluorescence / chemiluminescence imaging system- Chemiluminescence gel imaging analysis system JS-1080Mini
- Product model: js-1080 Js-1080 Mini automatic chemiluminescence imaging analysis system is a professional chemiluminescence imaging analysis system. It can image the ECL light directly and obtain the experimental results. In the past, the laboratory mainly used darkroom exposure and pressing film for ECL detection, but the construction of darkroom cost is high, laboratory space is wasted, exposure steps are cumbersome, and toxic chemical reagents will be exposed when developing X-ray film. The use of chemiluminescence imaging system has gradually replaced the traditional darkroom compression exposure detection.
- 0512-67158275hsy_001@hsy515.cn
-
Product introduction
The results of chemiluminescence analysis can be obtained by direct imaging of chemiluminescence system. In the past, the laboratory mainly used darkroom exposure and pressing film for ECL detection, but the construction of darkroom cost is high, laboratory space is wasted, exposure steps are cumbersome, and toxic chemical reagents will be exposed when developing X-ray film. The use of chemiluminescence imaging system has gradually replaced the traditional darkroom compression exposure detection.
Performance characteristics
Through the perfect combination of F / 0.80, high-definition large aperture high-pass fixed focus lens and high-sensitivity digital refrigeration CCD, the experimenter can get rid of the cumbersome traditional darkroom X-ray film exposure method, and obtain the experimental results of chemiluminescence quickly and efficiently.
The focus and reflective light source can be controlled automatically by computer;
Real time observation of chemiluminescence images can be carried out by computer;
The marker image and chemiluminescence image can be automatically superimposed by one shot without any operation, and three kinds of chemiluminescence images with different effects can be generated automatically;
The imaging of Western blot results can be completed by one button shooting without knowing the exposure time
The number of continuous sampling can be set, and the exposure time can be terminated. The dynamic continuous shooting is convenient to obtain the experimental results with the best conditions and effects;
Scope of application
Western lightning, ECL, ECL plus, CDP star, supersignal, CSPD, lumiglo and other luminescent substrates were detected by chemiluminescence
technical parameter
Cooling CCD: high resolution and low illumination digital refrigeration CCD chip of American original brand (chip Sony icx814)
Cooling side: semiconductor refrigeration
Cooling temperature: 65 ℃ lower than the ambient temperature (absolute temperature - 45 ℃, dynamic adjustable, real-time display of CCD refrigeration temperature)
Effective pixels: 3296 x 2472 (8.15 million pixels)
Pixel merging: 1 × 1, 2 × 2, 3 × 3, 4 × 4
Power zoom lens: F / 0.80, 4 / 3 inch high definition large aperture high pass through fixed focus lens, focus can be adjusted by computer
Data bits: 16 bits (65536 gray scale)
The pixel size: 5.5 x 5.5um
Dynamic range: > 4 orders of magnitude
Zoom: drawer type dual position object focusing platform is equipped as standard, which can be compatible with shooting samples of various thicknesses
The marker image and chemiluminescence image can be superimposed automatically without any operation in one shot, and three kinds of chemiluminescence images with different effects can be generated automatically;
One click shooting: no need to speculate on the exposure time and complete the imaging of Western blot results with one button
Auxiliary light source: transmission: LED white light plate; bilateral reflection: reflected white light (cold light). The intensity of transmission and reflection white light can be adjusted by computer
Filter lens: None
Control: highly programmed computer controlled black box
Timed shutdown: 0-60 minutes timed shutdown function
Shooting area: 20 × 20cm
The UV transmission sample plate: none
Quality enterprise certification: the third prize of "high tech enterprise" and "Shanghai Science and Technology Award"
Appearance size: length 39cm × width 35cm × height 59cm
Software: ECL SensiAnsys professional gel image acquisition and analysis software
ECL SensiCapture professional gel image acquisition software